PM सूर्य घर सब्सिडी ₹78,000 तक — पेपरवर्क में हम पूरी मदद करते हैं।
मुख्य सामग्री पर जाएं
House of Solar (HOS) logo

How Much Electricity Does a Heat Pump Use?

A simple method to estimate a heat pump’s electricity use and running cost from your hot-water demand, temperature and the datasheet COP.

लेखक House of Solar (HOS) team अंतिम अपडेट: 2 मिनट पढ़ें

Short answer: a heat pump's electricity use equals the heat your water needs divided by its coefficient of performance (COP) at your conditions. Work out the heat from your daily volume and temperature rise, take the COP from the datasheet, and multiply the result by your tariff for the running cost.

Step 1: the heat your water needs

Heating water takes a fixed amount of energy:

Heat (kWh) ≈ litres × temperature rise (°C) × 0.00116

For example, heating 100 litres from 20 °C to 45 °C (a 25 °C rise) needs about 100 × 25 × 0.00116 ≈ 2.9 kWh of heat. Do this for your total daily volume.

Step 2: the COP at your conditions

The COP tells you how many units of heat the heat pump delivers per unit of electricity. It changes with:

  • Air temperature — lower on cold winter mornings
  • Water temperature — lower when you ask for hotter water
  • Model and maintenance — a dirty coil or scaled heat exchanger lowers it

Use the manufacturer's data for conditions close to Jaipur's winter mornings if you want a conservative estimate.

Step 3: electricity and running cost

  • Electricity (kWh) ≈ heat needed ÷ COP
  • Running cost ≈ electricity × your tariff

Add a margin for standing losses from the tank and pipes, which depend on insulation and how long water is stored.

What changes real-world consumption

  • Set temperature: every extra degree costs efficiency. Set only as hot as the outlets need.
  • Insulation: poorly insulated tanks and recirculation loops lose heat continuously.
  • Timing: reheating the tank when the air is warmer, or when rooftop solar is generating, reduces grid electricity.
  • Maintenance: clean coils, correct water flow and descaling keep the COP close to the datasheet.

Why this matters for hotels and hostels

In buildings with large daily hot-water use, small differences in efficiency add up over the year. This is where a correctly sized heat pump with good storage and insulation is most valuable.

Next step

Share your daily hot-water use and we can estimate consumption for your building. See heat pump solutions in Jaipur or request a site survey.

  • #heat pumps
  • #running cost
  • #energy
शेयर करें: